Design of Sheds
Relevant Australian Standards
AS/NZS 1170.0 General Principles
AS/NSZ 1170.1 Permanent and Imposed Actions
AS/NSZ 1170.2 Wind Actions
AS NSZ 1170.4 Earth Quake Actions
Member Design Standards
AS/NZS 4600 Cold Formed Steel Structures
AS 4100 : Steel Structures
AS/NZS 5131 Fabrication and Erection of Structural Steelwork
The Foundation Standards
AS 2870 Residential Slabs and FootingsAS 3600 Concrete Structures
AS 2159 Piling Design and Installation
Material Specifics
AS/NSZ 3679.1 Hot Rolled bars and sections
AS/NZS 1163 Cold formed structural steel hollow sections.
AS/NSZ 1397 Steel sheet and strip
-

Minimum Pocket Depth for Coloumns
What is the minimum pocket depth required for rebated coloumns
The minimum washer size is 3 mm. This could be different. If nothing is mentioned use 3 mm.
The minimum bolt stick out should be 1 pitch. For M20 it is 2.5 mm. Use 10 mm stick out.
Also there is grout. Pockets when cast could be of different depths. Use design grout of 15 mm minimum.
The top of the bolt should be 35 mm below slab level to prevent concrete Cracking.
Hence to be practical use 100 mm pocket depth with a base plate thickness of 16 mm and bolt size of 20 mm.
-
Foot Bridges | WalkWays | Pedestrian over passes
-
Foot Bridges | WalkWays | Pedestrian over passes
-

Warrnambool Foot Bridge
-
-

Precast Blogs
-
Chalet 1 – White Horse Village

We are proud to showcase our contribution to Chalet 1 – White Horse Village, a unique and technically demanding project located in a mountainous region. This development presented several engineering and detailing challenges, and our team was honoured to be part of the solution — delivering precision, coordination, and innovation from start to finish. Technical…
-
PREFABRICATED CONCRETE ELEMENTS
(Temporary Fixing Inserts for As-Cast Element Tolerances) INTRODUCTION: To ensure proper alignment and structural efficiency in the handling and installation of prefabricated concrete elements by placing temporary fixing inserts within the allowable as-cast dimensional tolerances as specified in Australian Standard AS 3850.2:2015. Inserts for the temporary attaching of prefabricated concrete elements shall be placed within…
-
STAGGERED FERRULES PLACEMENT ON PRECAST PANEL

The design drawings for one of our Precast Project we were working on suggests ferrules must be placed staggered as noted below. The Problem: However, these casting components, such as ferrules cannot be placed on both sides of a precast panel with a thickness of less than 250mm. This mainly causes ferrules to clash along…
-
-

Mount Alvernia College
Mount Alvernia College
Expert MTO. Fast. Low Cost call us on.
Expert Material Takeoff and Steel Estimation Services
Competitve pricing
Tel: 0425791837
-

Navigate a million Changes?
Meticulous Care – Expertise alone not sufficent
Meticulous Care – Expertise alone not sufficent With many many changes, Mulitple site meaures, point cloud data, unless the processes are good and the care is meticulous, the knowledge and expertise will not count Street Address ATL Station State NSW Country Australia Modeler Ganesh Kumar
With many many changes, Mulitple site meaures, point cloud data, unless the processes are good and the care is meticulous, the knowledge and expertise will not count
Street Address ATL Station State NSW Country Australia Modeler Ganesh Kumar -
.Net | Python Ruby on Rails
-
Autocad Plug-in: Creating Order Forms Automatically
Normally creating order forms are a nightmare. How does everyone else create order forms? I have no idea how people do it. They would have to manually count/iterate through every single block which exists in the model space and simultaneously note down the parts’ associated panel number(s). They could do it on their PC, or…
-
WPF Tunnelling – Explanation by analogy
Tunnelling – What is it? And no, I’m not referring to how El Chapo escaped. Refresher: what is bubbling? In the last post we talked about “bubbling”. It’s kinda like those instances where you get a parking fine. If you don’t deal with it then, you’ll get another fine. If you don’t deal with…
-
What is a routed event?
What is a routed event? This is the answer that is typical on Stack Overflow sites and other such forums: A routed event is a type of event that can invoke handlers on multiple listeners in an element tree, rather than just on the object that raised the event. It seems – with all due…
-
What is an event?
Assumed knowledge: Assume you know what a method is. What is an event? Let’s keep it simple. An event is anything which “happens”. “Oh great! That helps a lot :’( ,“ I hear you say. Examples are in order: The President comes to town. He could come at anytime. You don’t know when he…
-
What is a call-back function?
Example by Parable and Analogy I have a secretary. At the end of the day, I ask her to: (i) take the firm’s outgoing mail and to drop it off at the post office, and in addition to that, after she has dropped the mail off, I ask her to do something else: (ii) whatever…
-